Construction | |
|
Conductor | |
|
Material |
Solid annealed copper conductor |
|
Nominal diameter (mm) |
24AWG |
|
Insulation | |
|
Material |
Polyethylene |
|
Normal thickness (mm) |
0.21 |
|
Insulation nominal outer diameter (mm) |
0.90 |
|
Twisted pair Chromatogram | |
|
Stranding construction |
1*4 |
|
Lay |
100mm |
|
Screen |
Aluminum foil |
|
Thickness (mm) |
0.05 |
|
Drain wire |
Tinned copper wire |
|
Nominal diameter (mm) |
24AWG |
|
Sheath | |
|
Material |
PVC |
|
Minimum average thickness (mm) |
0.5 |
|
Cable maximum diameter (mm) |
6.5 |
|
Electrical | |
|
Single conductor resistance |
9.5Ohms/100m |
|
Pair DC resistance unbalance |
2.5% |
|
Dielectric intensity between conductors, DC, 1min |
1 kV |
|
Dielectric intensity between conductors, DC, 2min |
5.6 nF/100m |
|
Mechanical | |
|
Conductor breaking elongation rate |
more than 10% |
|
Insulation tension |
more than 16MPa |
|
Insulation breaking elongation |
more than 300% |
|
tension before aging |
more than 12.5MPa |
|
Insulation breaking elongation before aging |
more than 125% |
|
tension after aging |
more than 12.5MPa |
|
Insulation breaking elongation after aging |
more than 125% |
Cross section





US...