- Home
// Products - // Accessories
- // HP ProCurve Networking
- // FCC
- // Switches
- // Power Supplies
HP ProCurve 600 Redundant and Ext PS
Manufacturer PN #: J8168A#ABA
List Price: $1699.00
Please Login to see Your Price.
Quantity on Shelf: Login
Quantity on Order: -
HP ProCurve 600 Redundant External Power Supply (J8168A)
The ProCurve 600 Redundant and External Power Supply (RPS/EPS) has 6 RPS ports and 2 EPS ports and supplies backup and Power over Ethernet power.
Ports
6 redundant power supply ports
Restrictions: Each port can provide redundant +12 V power to a connected switch; only one port can provide power at a given time
2 external power supply ports
Restrictions: Provides 50 VDC external PoE to up to two ProCurve switch devices; provides max. of 408 W full power to one device, and half power (204 W each) if connected to two devices
Physical characteristics
Dimensions: 12.83(d) x 17.44(w) x 1.73(h) in. (32.59 x 44.3 x 4.39 cm) (1U height)
Weight: 11.78 lb. (5.34 kg), Fully loaded
Mounting
1U rack-mountable and wall-mountable enclosure using standard mounting hardware
Environment
Operating temperature: 32ºF to 131ºF (0ºC to 55ºC)
Operating relative humidity: 15% to 95% @ 104ºF (40ºC), non-condensing
Non-operating/Storage temperature: -40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity: 15% to 95% @ 149ºF (65ºC), non-condensing
Altitude: up to 15,000 ft. (4.6 km)
Acoustic: Noise emission LwA=59.2 dB at virtual workspace, according to DIN 45635 T.19
Electrical characteristics
Description: The unit automatically adjusts to any voltage between 100-240 V and either 50 or 60 Hz
Voltage: 100-240 VAC
Current: 9 / 5 A
Maximum power rating: 800 W
RPS power: 180 W
PoE power: 408 W
Frequency: 50 / 60 Hz
Notes: Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Safety
CSA 22.2 No. 60950
EN 60950/IEC 60950
UL 60950
Emissions
FCC Class A
VCCI Class A
EN 55022/CISPR 22 Class A
Immunity
EN: EN 55024, CISPR 24
ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated: IEC 61000-4-3; 3 V/m
EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.05 kV (signal line)
Surge: IEC 61000-4-5; 1 kV/2 kV AC
Conducted: IEC 61000-4-6; 3 V
Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics: EN 61000-3-2, IEC 61000-3-2
Flicker: EN 61000-3-3, IEC 61000-3-3
Management
Provides information via port interfaces of attached devices
Notes
Supported devices
*HP ProCurve Switch 2600-PWR Series, ProCurve Switch 2610 Series, ProCurve Switch 2610-PWR Series, ProCurve Switch 2800 Series, ProCurve Switch 2810 Series, ProCurve Switch 5300xl Series, ProCurve Switch 3400cl Series, ProCurve Switch 6400cl Series, and ProCurve Secure Router 7000dl Series