Alvarion Breeze ACCESS II, Includes qty 20 of the following: SU-I-D-1D-2.4, Uni-24, 20ft RG-8, AL-1 with 10ft cable, pig tail 7", coax seal tar packs. Mfr#: 929119 |
The miniature indoor units, designed primarily for indoor installations, are comprised of a single desktop or wall-mountable unit.
- The SU-ID products have two RF connectors for detached diversity antennas.
Package Includes:
- Radio Unit with 10BaseT Port (1 Data User support)
- Detached Diversity Antenna port
- Lightning arrestor
- 100-240 VAC Power Supply
|
| RADIO |
| Frequency |
2.4GHz ISM band |
| Radio Access Method |
FH-CDMA |
| Operation Mode |
Time Duplex Division |
| Standards |
ETSI ETS 300 328, FCC Part 15 |
| Channel Bandwidth |
1MHz |
| Output Power (at antenna port) |
17dBm (FCC) or 0dBm (ETSI) |
| Sensitivity |
Data Rate |
|
| (dBm at antenna port, BER 1E10-6) |
1Mbps |
-80 |
| 2Mbps |
-74 |
| 3Mbps |
-66 |
| Data Rate |
3Mbps max. |
| Modulation |
Multilevel GFSK |
| CONFIGURATION AND MANAGEMENT |
| Local Management |
Via MON port, Monitor program using terminal emulation |
| Remote Management |
SNMP, Telnet, TFTP, Windows-based Configuration Utility |
| Remote Management Access |
Management Access list filtering, from Ethernet or from the wireless link |
| SNMP agents |
MIB II, Bridge MIB, BreezeACCESS Private MIBs |
| Accounting |
RADIUS compatible client in subscriber units |
| Software upgrade |
TFTP download |
| SECURITY |
| Security |
RC4 Authentication, IP Address Access List, Protocol Filtering and Virtual LAN |
| INTERFACE |
| RF (antenna ) |
2 x SMA jacks |
| Ethernet |
Indoor units: 10BaseT,(RJ-45) with 2 embedded LEDs |
| Monitor |
Indoor units: 3-pin low profile |
| Power |
DC power plug to external power supply |
| ELECTRICAL |
| Electrical |
5VDC/ 0.5A from external power supply |
| MECHANICAL |
| Mechanical |
13cm x8.6 cm x 3 cm 0.5 kg. |
| ENVIRONMENTAL |
| Operating Temperature |
0° C to 40° C |
32° F to 104° F |
| Operating Humidity |
5% to 95% non-condensing. |
| STANDARDS COMPLIANCE , GENERAL |
| EMC |
EN 300-385, FCC Part 15 |
| Safety |
EN 60950, UL 1950 |
| Environmental |
ETS 300 019, Bellcore GR-63-CORE | |