The SM is the subscriber termination unit or the Customer Premise Equipment (CPE). It consists of a single module that operates with an integrated 60-degree antenna. Each SM can communicate to a single AP Module at any given time. SM synchronization and control is accomplished via the received AP signal. SMs are typically located outdoor and Line of Sight (LOS) from the APs. Once the SM is initialized, it scans the Radio Frequency (RF) channels and automatically registers with the appropriate AP. |
| Package Includes: |
| P/N |
Description |
Quantity |
| 5750SM |
5.7 GHz Advantage Subscriber Module |
25 |
| Attention! |
90-230VAC Power Supply-Euro |
Not Included |
| Attention! |
Canopy Universal Mounting Bracket |
Not Included |
SM Module Specifications:
| Description |
5.7 GHz Advantage Subscriber Module |
| Canopy Part Number |
5750SM |
| Signaling Rate |
20 Mbps Maximum |
| Typical LOS Range |
2 Mile (3.2 km) max |
| Typical Aggregate Useful Throughput |
14 Mbps Maximum |
| Frequency range of band |
ISM 5725-5850 MHz |
| Non-overlapping Channels |
6 |
| Channel Width |
20 MHz |
| Channel Spacing |
every 5 MHz |
| Modulation Type |
High Index 2-level Frequency Shift Keying (FSK) optimized for interference rejection |
| Encryption |
DES Capable |
| Latency |
5-7 msec |
| Carrier to Interference ratio (C/I) |
~3dB @ 10 Mbps, ~10dB @ 20 Mbps at -65dBm |
| Nominal Receiver Sensitivity (dbm typical) |
-86 dB |
| Antenna Gain (dB) |
7 dB |
| EIRP (dB) |
30 dB |
| Equivalent Isotropic Radiated Power (EIRP) |
1W |
| DC Power (typical) |
0.3 A @ 24 VDC = 7.2 W |
| Antenna Beam Width |
3 dB antenna beam width 60 degrees, Azimuth and Elevation |
| Temperature |
-40° C to +55° C (-40° F to +131° F) |
| Wind Survival |
190 km/hr (118 miles/hr) |
| Dimensions |
11.75 in H x 3.4 in W x 3.4 in D (29.9 cm H x 8.6 cm W x 8.6 cm D) |
| Weight |
.45 kg (1 lb) |
| Access Method |
Time Division Duplexing/Time Division Multiple Access (TDD/TDMA) |
| Interface |
10/100 Base T, half/full duplex. Rate auto negotiated (802.3 compliant) |
| Protocols Used |
IPV4, UDP, TCP, ICMP, Telnet, HTTP, FTP, SNMP |
| Network Management |
HTTP, TELNET, FTP, SNMP Version 2c |
| FCC ID |
ABZ89FC5804 |
| Industry Canada Certification Number |
109W-5700 |
| NYCE |
0202CE08128 | |