ELECTRICAL SERVICE:
Ethernet
Signal Voltage ............................................................................................... 55 VDC
Transfer rate .....................................................................................................CAT-5
Configuration..................................................................................................... 2 pair
Input Connection ................................................... Screw-Term Block (24-16 AWG)
Protection Modes.......................................................... Line to Line, Line to Ground
Maximum Continuous Operating Voltage .................................................. 90 VDC
VDC
Service Voltage ............................................................................................. 55 VDC
Configuration........................................................................................... up to 4 wire
Input Connection .................................................. Screw-Term. Block (24-16 AWG)
Protection Modes.......................................................... Line to Line, Line to Ground
Maximum Continuous Operating Voltage .................................................. 90 VDC
Reset Wire/LED Signal Wire
Service Voltage ............................................................................................. 55 VDC
Configuration............................................................................................. 1 wire (ea)
Input Connection .................................................... Screw-Term Block (24-16AWG)
Protection Mode............................................................ Line to Line, Line to Ground
Maximum Continuous Operating Voltage ................................................... 90VDC
ELECTRICAL PERFORMANCE:
3Tested to IEEE/ANSI C62.41 10/1000ms Long Wave
Peak Current..............................................................................................150A peak
Voltage Protection Level ...............................................130Vpk @ 150A 10/1000ms
Tested to IEEE/ANSI C62.41 8/20ms Combination Wave
Peak Current............................................................................................1500A peak
Voltage Protection Level ...................................................152Vpk @ 1500A 8/20ms
Peak Power Dissipation ...............................................................................20,000 Watts
Response Time (Max.)...............................................................................5 nanoseconds
ENVIRONMENTAL:
Operating Temperature:............................................................................-40°C to +80°C
Storage Temperature: ...............................................................................-40°C to +80°C
Relative Humidity:...........................................................................99%(non-condensing)
MECHANICAL/INSTALLATION:
Refer to Transtector Installation Instruction document 1200- 148 for further information regarding the installation of this product.
Enclosure dimensions: The suppressor is housed in a molded plastic enclosure that is 6.13 in long, 4.5 in wide and 2.5 in tall.
Mounting data: The enclosure mounts with #6 hardware.
Wiring data: The ALPU-ALVR surge suppressor is designed to accept (2) multiconductor cables with outside diameters of up to 0.375".

|